4.3 Electrical data
Connections
DIN EN 175301-803 Form A:
for cable plug Type 2511
Supply voltage
24 V / 110 V / 230 V / 240 V AC/DC
± 10 %
Voltage tolerance
Power consumption
4 W Operation, 72 W Inrush
4.4 Type label
Orifice
Operating principle
Type
2610 A 6,0 PTFE
G1/4
P N 0 - 10 bar
24 V
AC/DC 72/4W
00167737
Identification number
Voltage, Frequency, Power consumption
Connection thread, Pressure range
5.1 Fluid installation
Installation position: any, preferably magnetic system upright.
→
Check pipelines and flange connections for dirt and clean.
→
Install a dirt filter before the valve inlet (0.2 ... 0.4 mm).
Observe direction of flow! The arrow on the body indicates the
direction of flow.
NOTE!
Caution risk of breakage!
▶ Do not use the coil as a lever arm.
→
Hold the device with a open-end wrench on the body and screw
into the pipeline.
6
5.3 Rotation of the coil
WARNING!
Electric shock!
If the protective conductor contact between the coil and body is
missing, there is danger of electrical shock.
▶ Check protective conductor contact after installing the coil.
Overheating, Risk of fire!
Connection of the coil without pre-assembled valve will result in
overheating and destroy the coil.
▶ Connect the coil with assembled valve only.
The coil can be turned by 4 x 90°.
→
Loosen nut.
→
Turn coil.
→
Tighten nut with a open-end wrench
(max. 5 Nm).
Seal material
Body material
VA
W17MG
Arrow indicating
direction of flow
english
Nut
(max. 5 Nm)
Valve
5
INSTALLATION
DANGER!
Risk of injury from high pressure in the equipment!
▶ Before loosening the pipes and valves, turn off the pressure and vent
the lines.
Risk of injury due to electrical shock!
▶ Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
WARNING!
Risk of injury from improper installation!
▶ Installation may be carried out by authorized technicians only and with
the appropriate tools.
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following assembly, ensure a controlled restart.
english
5.2 Electric installation
WARNING!
Risk of injury due to electrical shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
If the protective conductor contact between the coil and body is
missing, there is danger of electrical shock!
▶ Always connect protective conductor.
▶ Check electrical continuity between coil and body.
Only operate the device with the cable plug of Type 2511
supplied.
Note the voltage and current type as specified on the type label.
→
Check that seal is fitted correctly.
→
Screw cable plug Type 2511 tightly onto coil
(min. 0.5 Nm, max. 0.8 Nm).
6
MAINTENANCE, TROUBLESHOOTING
WARNING!
Risk of injury from improper maintenance!
▶ Maintenance may be carried out by authorized technicians only and
with the appropriate tools.
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following maintenance, ensure a controlled restart.
If malfunctions occur, check:
• the line connectors,
• the operating pressure,
• the power supply and valve control.
If the valve still does not switch, please contact your Bürkert Service.
english
Type 2610
5
7