7.7. electrical data

Connections:
DIN EN 175301-803 Form A
for cable plug Type 2508
Supply voltage:
24 V DC ± 10 % -
max. residual ripple 10%
24 V / 50 Hz
230 V / 50 Hz
± 10%
Voltage tolerance:
Nominal output:
8 W
Impulse version
7 W
Nominal operating mode: 100% continuous operation
for block installation
5 W continuous operation
on request
8 W intermittent operation 60%
(30 min)
Note the information specified on the type label for
voltage, type of current, and pressure.
english
16

8.2. fluid installation

Danger!
Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the pres-
sure and vent the lines.
Installation position:
any, actuator preferably upwards.
Procedure:
Before installation, clean any possible dirt off the pipe-
lines and flange connections.
If required, install a dirt trap to prevent malfunctions.
Pay attention to the flow direction of the valve.
from 1(P) → 2(A) (CF C) or
from 1(P) → 2(B) (CF D)
english
18
Mesh size:
0.2 – 0.4 mm
8.
insTallaTiOn
8.1. safety instructions
Danger!
Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the
pressure and vent the lines.
Risk of injury due to electrical shock!
• Before reaching into the system, switch off the power
supply and secure to prevent reactivation!
• Observe applicable accident prevention and safety
regulations for electrical equipment!
Warning!
Risk of injury from improper installation!
• Installation may be carried out by authorized techni-
cians only and with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following installation, ensure a controlled restart.
Valve with threaded connection:
Use PTFE tape as sealing material
note!
Caution risk of breakage!
• Do not use the coil as a lifting arm.
Hold the device with a suitable
tool (Open-end wrench) on the
body and screw into the pipeline.
Valve with flanged connection:
Remove the cover plate.
Loosen the nut on the coil and remove coil.
Type 6014
english
17
17
english
19
19