Where message is displayed:
Home Screen
Inventory Screen
Microinverter
grid
configuration
failure cleared
after xx
attempts
Module
Sleeping
Sleeping
No Grid Profile
No Grid Profile
Over
Over Temperature
Temperature
Power
Power generation
generation off
off by command
by command
Power On
Power On Reset
Reset
Shutdown
Startup
Transient Grid
Transient Grid
Profile
Profile
44
Description
Description: A failed attempt to change the grid profile for the
microinverters has cleared. The grid profile was successfully applied
to the microinverters. No action is required.
xx = number of attempts
Description: The Microinverter is off for the night.
No action is required.
Recommended Action: Use the Envoy Gateway web interface to
select a grid profile for this system. For more information refer to
"Configure Grid Profile" on page 12.
Description: The Envoy has not been set up with a grid profile for
the microinverters. Microinverters must be configured with the
appropriate grid profile before they will produce energy.
Description: The microinverter is too hot and is not producing
power.
This very rare condition usually clears without intervention. No action
is required unless the condition persists. If it persists, contact
Enphase Energy customer support.
Description: The microinverter is not producing power by user
command.
This uncommon condition will occur only during isolated
troubleshooting procedures by Enphase personnel. No action is
required.
Description: The microinverter has powered on after having both AC
and DC disconnected.
No action is required.
Description: The Envoy has been powered down (unplugged from
AC power).
Restore AC power to the Envoy.
Description: The Envoy has been powered back up (plugged back in
to AC power).
No action is required.
Recommended Action: No action is required. This condition will
clear once the grid profile test is complete.
Description: This system is currently in test mode.