Code
Level Descr.
dS2
1
Defrost end temperature for the second evaporator
The probe 3 temperature above which defrosting for the second
evaporator is ended. If, at the start of a defrosting cycle, the
temperature is greater than that set, no defrosting will be carried out.
In the event of a probe 3 malfunction, the defrosting cycle will in any
case terminate after reaching a time limit.
This function is only enabled if P01=3o4, Co4=3 and CP0=2 (alarm
relay used for second evaporator defrosting and probe 3 used to
detect the temperature of the second evaporator). In this case, the
dripping phase will begin after the defrosting cycles of both
evaporators have ended.
dPO
1
Defrosting at power-on
0 = disabled
1 = defrosting when the instrument is switched on
List of -FAn fan parameters
FSt
1
Fans switch on temperature
Fot
1
Fans switch off temperature
FAd
1
Fans switch on and off differential
Fdt
1
Post-dripping time
The time after the dripping phase, during which the fans remain
switched off
dt
1
Dripping time
The time after a defrosting cycle during which the compressor and the
evaporator are stopped in order to favour evaporator dripping
dFd
1
Fans deactivated during defrosting
0 = fans activated (operation set from FPt)
1 = fans deactivated
FCO
1
Fans activated with compressor off
0 = fans deactivated
1 = fans activated (operation set from FPt)
2 = fans in duty cycle operation
Fon
1
Fans ON time during duty cycle operation (FCO=2)
FoF
1
Fans OFF time during duty cycle operation (FCO=2)
List of -ALr alarm parameters
AFd
1
Temperature alarm threshold differential
This sets the re-entry temperature threshold after a high- or low-
temperature alarm condition
HAL
1
Maximum alarm threshold
Above this value (absolute or referred to the setpoint) an alarm is
triggered
If the reference is relative, the unmarked value is added to the setpoint
LAL
1
Minimum alarm threshold
Below this value (absolute or referred to the setpoint) an alarm is
triggered
If the reference is relative, the unmarked value is subtracted from the
setpoint
PAO
1
Temperature alarm delay at power-on
dAO
1
Temperature alarm delay after defrost
The time, starting from the end of the dripping phase, during which no
alarm is signalled.
In the event of contemporaneous network defrosting, the time refers to
the defrosting end command
OAO
1
Temperature alarm delay after door closure
The time, after the door is closed again and during which no alarm is
signalled
dAt
1
Defrosting alarm timeout enabling
This enables the signalling of any defrosting end due to the maximum
time limit being reached (timeout).
0 = signal disabled
1 = signal enabled
probe2 ≥ FSt: fans off
Fot ≤ probe2 < (FSt –
FAd): fans on
probe2 < (Fot – FAd): fans
off
Range
Unit
MBP
-50.0 ...
°C [°F]
10
199.0
0,1
flag
0
-50.0 ...
°C [°F]
8
199.0
-50.0 ...
°C [°F]
-50
199.0
1.0 ...
°C [°F]
2
90.0
0 ... 60
min
1
0 ... 60
min
2
0,1
flag
1
0 ... 2
0
1 ... 60
min
15
1 ... 60
min
15
1.0 ...
°C [°F]
2
90.0
-50.0 ...
°C [°F]
10
199.0
-50.0 ...
°C [°F]
-10
199.0
0 ... 10
h
4
0 ... 999
min
60
0 ... 10
h
0
0,1
flag
0
P-SF-SV Pag. 53 REV 00 02/11
UK
LBP
HBP
(non
per SV)
10
10
0
0
-5
50
-50
-50
2
2
2
0
2
0
1
0
0
0
15
15
15
15
2
2
10
10
-10
-10
4
4
60
60
0
0
0
0

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

SfSv

Table des Matières