4. Remove needle from front of gun.
Wipe or flush fluid from nozzle and needle. If necessary,
clean retaining ring, air cap, air cap guide, and spring.
NOTICE:
Do not use metal tools to clean the fluid nozzle or air cap
holes as this may scratch them, causing fluid leaks and a
distorted spray pattern.
Original instruction
6. Using a squeeze bottle, flush cleaning fluid through the
gun. Hold the gun upside down, pull the trigger, and dis-
pense cleaning fluid into the cup connection.
7. Re-install needle and move trigger slide from NEEDLE
REMOVAL position (B) to SPRAY position (A).
8. Trigger the gun and install spring, air cap guide, and
fluid nozzle. Install air cap and retaining ring.