Storch HVLP SmartFinish 360 Mode D'emploi page 96

Masquer les pouces Voir aussi pour HVLP SmartFinish 360:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
Troubleshooter
Problem
Sprayer not starting
No material transport
Insufficient atomising
Circuit breaker triggered
TurboControl LED indi-
cator flashing
The
device
stopping
during spraying.
Original instruction
1. Check all potential error and their causes before disassembling the
device.
Cause
No power
Sprayer automatically switches off in
the AUTO-START setting
No material
No pressure on cup
Gun hose blocked
Material inlet blocked
Position of needle safeguard
UNLOCK
Gun dirty
Air filter dirty
Extension cable too long
Air hose too long
Leaks with air hose connections
Air filter dirty
Wrong mains voltage
High ambient temperature
Motor defective
Air filter dirty
Circuit breaker
Air filter dirty (TurboControl LED indi-
cator flashing)
AUTO-START activated
Action
Check socket outlet. Press ON/OFF switch.
Check whether the correct power cord is being
used and is inserted.
Reset circuit breaker. Reset by pressing.
Check the air valve before opening the gun. Press
the gun.
Check whether cup contains material. See filling
of the cup system,
Check cup system for leaks. See cup system sec-
tion
Check gun hose for blockages. Clean or replace
the gun hose, as required.
Cup system: Check filter screen and inlet tip for
blockages.
Check position of needle safeguard. Trigger pin
must be in SPRAY position.
Clean gun. See cleaning the gun.
Clean turbine and motor air filter. Replace as re-
quired. See clean filter.
Extension cable must have triple core, at least 2.5
mm
, max. 15 m long.
2
Replace with shorter hose, no shorter than 6.1 m.
Disconnect all hose connections and securely
connect again.
Clean turbine and motor air filter. Replace as re-
quired. See clean filter.
Ensure correct mains voltage for sprayer model.
Move sprayers to a cooler area.
Contact the STORCH hotline
Clean turbine and motor air filter. Replace as re-
quired. See clean filter.
See section above "Circuit breaker triggered".
Clean turbine and motor air filter. Replace as re-
quired. See clean filter.
Release gun trigger and operate gun again. Set
the switch to the ON position to turn off AU-
TO-START.
96

Publicité

Table des Matières
loading

Table des Matières