Inspection And Maintenance - Güde GFO 1401 Mode D'emploi

Masquer les pouces Voir aussi pour GFO 1401:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
wait 5 to 10 sec. and then turn the tool back
on again.
Overloading reasons
1.
Power cord is too long or has small diameter.
Secure proper extension cable with minimum
diameter of 1,5 mm
2. Saw blade is not sharp enough. Sharp it up.
Saw blade teeth have not sufficient rake.
Burned marks on the workpiece
1. saw blade is dull. Let it sharpen up or eplace
it.

Inspection and maintenance

Plug the cord out before any activity
to clean plastic parts use a damp cloth.
Never use any detergents, neither
dissolvents or sharp tools.
Remove dirt of the table with proper cleaning
spray.
If it takes more then 10sec. to stop the motor,
replace the worn out brakeparts in qualified
workshop.
Ventilation holes and moving parts always
clean up from the dust with soft brush after
each use.
Lubricate metal moving parts regularly.
Saw blade mounting and
dismounting (pict. 29+30)
Attention! Always disconnect the power plug
before any maintenance or adjustment and
before removing or installing the saw blade.
Press the lever (pict. 29) and hold it to loose the
saw blade.
To loose adjustment bolt holding the saw blade
use socket wrench or open-ended wrench.
Loose the bolt clockwise (pict.30).
2
Take the saw blade off the spindle and remove
it.
Clean the spindle up and put a new saw blade
on.
Put a new saw blade on and secure it in
opposite way as described above.
Attention! Check the rotation direction. Confirm
that cutting edge of teeth match with the
direction of rotation, i.e. forward. Watch out for
the arrows on the saw blade and saw blade
guard.
Every time before use check if all protective and
safety equipment function correctly.
Important! After you mounted on a new saw
blade check by hand if it spins freely.
Then plug the power back in and trial run the
tool before you start working on it.
Safety instructions for
inspection and maintenance
Only well maintained tool, which is well cared
about will guarantee proper function. Insufficient
and careless maintenance can result in injuries
and harms.
Inspection and maintenance
After each use
Remove dust form all ventilation holes and
moving parts.
After each use
Remove dust from whole saw.
Regularly
Lubricate metal parts (with universal oil)
Regularly
Check all bolts if they are tight. Vibrations can
cause their loosing.
13