electrical data
Connections:
2 threaded connections ISO 20
Limit switches:
2 limit switches for the motor
2 potential-free limit switches (for position feedback)
Output:
max. 250 V AC / 5 A
electrical data for standard version without analogue signal and position controller version with 4 – 20 ma,
0 – 20 ma or 0 – 10 V analogue input signal
torque [nm]
25
45
75
100
150
300
600
1000
We recommend an actuator designed with 1.5 times the maximum torque of the fitting (with 2 times
the maximum torque for variable speed actuators)
The operating
voltage must not drop below 11.5 V
1)
90° actuating time [s]
7
15
20
15
30
60
38
38
power input [W]
45
100-240 / 50/60 (100-350 DC)
15-30 AC (12-48 DC
45
100-240 / 50/60 (100-350 DC)
15-30 AC (12-48 DC
45
100-240 / 50/60 (100-350 DC)
15-30 AC (12-48 DC
45
100-240 / 50/60 (100-350 DC)
15-30 AC (12-48 DC
45
100-240 / 50/60 (100-350 DC)
15-30 AC (12-48 DC
45
100-240 / 50/60 (100-350 DC)
15-30 AC (12-48 DC
250
100-240 / 50/60 (100-350 DC)
15-30 AC (12-48 DC
250
100-240 / 50/60 (100-350 DC)
15-30 AC (12-48 DC
English
Voltage / frequency
[V / hz]
)
1)
)
1)
)
1)
)
1)
)
1)
)
1)
)
1)
)
1)
19