1
OPERATING INSTRUCTIONS
The operating instructions contain important information.
▶ Read the operating instructions carefully and follow the safety instruc-
tions in particular, and also observe the operating conditions.
▶ Operating instructions must be available to each user.
▶ The liability and warranty for the type 2610 are void if the operating
instructions are not followed.
1.1 Symbols
▶ Designates an instruction to prevent risks.
→
designates a procedure which you must carry out.
Warning of injuries:
DANGER!
Imminent danger! Serious or fatal injuries.
WARNING!
Potential danger! Serious or fatal injuries.
CAUTION!
Danger! Minor or moderately severe injuries.
Warns of damage to property:
NOTE!
2
2.3 Predictable misuse
The device must not be insulated more than 2 cm from
the edge of the body upwards to the coil.
3
BASIC SAFETY INSTRUCTIONS
These safety instructions do not make allowance for any contingencies
and events which may arise during installation, operation and maintenance.
Danger – high pressure!
▶ Before loosening the lines and valves, turn off the pressure and vent
the lines.
Risk of electric shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for
electrical equipment!
▶ Installation and repair work may be carried out by authorized techni-
cians only and with the appropriate tools.
▶ After an interruption in the power supply or pneumatic supply, ensure
that the process is restarted in a defined or controlled manner.
▶ Do not put any loads on the body.
▶ The general rules of technology apply to application planning and
operation of the device.
4
TECHNICAL DATA
4.1 Operating conditions
WARNING!
Risk of injury from hot/cold and aggressive media!
Heat sources or temperature fluctuations may cause malfunctions or
leaks.
▶ Avoid heat sources which may cause the permitted temperature
range to be exceeded.
▶ Before use, check media resistance.
Ambient temperature
max. +50 °C
Medium temperature
–200...+180 °C
4
english
english
2
INTENDED USE
Incorrect use of the solenoid valve Type 2610 can be dangerous
to people, nearby equipment and the environment.
▶ The device is designed for blocking, dosing, filling and venting gas-
eous and liquid media.
▶ Use according to the permitted data, operating conditions and con-
ditions of use specified in the contract documents and operating
instructions.
▶ Correct transportation, correct storage and installation and careful use
and maintenance are essential for reliable and problem-free operation.
▶ Use the device only as intended.
▶ Check media resistance.
2.1 Restrictions
If exporting the system/device, observe any existing restrictions.
2.2 Definition of term
In these operating instructions, the term "device" always refers to the
solenoid valve Type 2610.
Risk of burns/risk of fire!
During continuous operation the surface of the device may become
hot.
▶ Keep the device away from highly flammable substances and media
and do not touch the device with bare hands.
▶ Do not obstruct the heat release required for operation.
Danger due to high/low temperatures!
The device may become extremely cold/hot depending on the tem-
perature of the media.
▶ Keep away from flammable/cold-sensitive substances and do not
touch with bare hands.
Destruction of the coil by overheating!
▶ Connect the coil electrically only when the body has been installed.
▶ In the case of AC voltage pay attention to movable core.
▶ Check media resistance.
General hazardous situations.
To prevent injury, ensure that:
▶ Do not feed in aggressive or flammable media.
▶ Do not make any internal or external changes. Ensure that the
system cannot be activated unintentionally.
english
Viscosity
21 mm²/s
Protection class with cable plug: IP65 in accordance with EN 60529,
Media
neutral gaseous and liquid media, which do not
attack body and sealing materials (see table of
resistance under www.burkert.com)
Check media resistance in individual cases
Cycling rate
max. 10/min
4.2 Fluidic data
Operating principle
2 (A)
A
2/2-way valve, normally closed
(NC)
1 (P)
Pressure range
see type label
Line connectors
G1/4, G1/2
Type 2610
NEMA 4X