Compressor runs without stop
D
In operation the relief valve
under the pressure switch
releases the pressurized air
E
After switch-off pressure is
reached the relief valve under
the pressure switch releases the
pressurized air until the switch-
on pressure is reached
F
Compressor switches on
frequently
G
Safety valve blows off
H
Compressor heats too much
I
The oil level rises without oil
being added
J
Compressor is overheated and
it switches off

Maintenance Table

Maintenance periods are valid for normal operating conditions; in case of
extreme operating conditions the maintenance periods are shortened correspondingly.
Actions
Intake suction filter check
• cleaning
• replacement
Cleaning of reverse valve and insert
Oil level check
Oil replacement
1. replacement of mineral oil
of synthetic oil
Filling up/adding the oil
Draining the condensation water from air
receiver
Draining the condensation water from
pressure reducing valve of the filter
Filter insert cleaning
Compressor cleaning
Screwing check
Suction filter is contaminated heavily
Pneumatic tool has too high air consumption
Leak at the compressor
Too much condensing water in air receiver
Leaky pneumatic piping
Mud-discharge valve is open or missing
Leaky relief valve
Insert of the non-return valve is leaky or faulty
Non-return valve is damaged
Too much condensation water in the air receiver
Compressor is overloaded
Pressure in the air receiver is higher than set-up
switch-off pressure
Safety valve is faulty
Intake air is insufficient
Cooling ribs at the cylinder (cylinder head) are
dirty
Too long period of use
Condensation water accumulates in oil
High air humidity
Compressor is overloaded
Compressor is faulty
Compressor has under voltage
Ambient temperature 35°C
Periods
Weekly every
50 hours of operation,
min. once a year
Yearly
Daily or more precisely before
every putting into operation
after 50 hours of operation
once a year
every two years
As required
After every use
After every use
As required
As required
First time after 10 hrs. of
operation, subsequently every
500 hrs. of operation
Clean or replace the suction filter
Check the air consumption of the pneumatic
tool; contact authorized reseller
Locate the leak, notify Güde service
Drain the condensing water
Check the pneumatic piping, seal the leak
Close or insert it
Clean or replace the relief valve
Clean or replace the insert of the non-return
valve
Replace the non-return valve
Drain the condensation water
Have the pressure switch readjusted /replaced
by an authorized person (Güde Service)
Replace the safety valve or contact Güde
Service
Make sure that sufficient intake and outlet of the
air is guaranteed (minimum distance from a wall
40 cm)
Clean the cooling ribs at the cylinder (cylinder
head)
Switch off the compressor
Compressor is overdesigned, notify the Güde
Service
Replace the oil
Notify the Güde Service
Notify the Güde Service
Notify the Güde Service