18.8. Use of the inverter's internal wattmeter or the external
wattmeter
These units can be used in different types of installation with different types of loads (critical and non-critical).
Depending on the type of loads in the installation, either the inverter's internal wattmeter or an external wattmeter
will be used.
The use of the inverter's internal wattmeter only allows managing loads connected at the unit's critical load output.
That is, only the management of critical loads.
The use of an external wattmeter allows to manage both the critical loads connected to the inverter and the
non-crit. loads connected to the distribution grid.
INFO
For more information about compatible external wattmeters, see the "List of compatible wattmeters for with
INGECON SUN STORAGE 1Play TL M", available on the Ingeteam website. If the wattmeter model is not in the
list, contact Ingeteam.
Stand-alone installations
In stand-alone installations the unit's internal wattmeter is used. All the loads that are managed are connected to
the inverter's critical load output.
UPS installations
In UPS installations the unit's internal wattmeter is used. The loads that are managed are connected to the
inverter's critical load output. The non-crit. loads connected to the grid side are not managed by the inverter.
Self consumption installations
In self consumption installations the external wattmeter located at the grid connection point is typically used. This
allows the inverter to manage all the existing loads in the installation, both critical and non-critical.
The unit's internal wattmeter may only be used in the event that all the loads are connected at the inverter's
critical load output.

18.9. Updating the inverter firmware

The simplest way to update the inverter firmware is through the web application, with an internet connection.
If there is no internet connection, it can also be updated via the web application itself, or from the unit's USB port.
Update via the web application, with internet connection
INFO
To perform this procedure, the inverter must be connected to the Internet through a Wi-Fi network or Ethernet.
1.
Open the web application from the device's browser (see
2.
Open the Update menu. If there are any updates available they will be listed.
3.
Install the update.
Update via the web application, without internet connection
INFO
To perform this procedure, the firmware file ABH1007 must be downloaded from the Ingeteam website.
1.
Open the web application from the device's browser (see
its Wi-Fi
network").
2.
Open the Update menu.
3.
Select the previously downloaded firmware file.
54
"18.5. Connecting to the inverter
"18.3. Connecting to the inverter locally through
ABH2014IQM01_A- Installation and Operation Manual
Using the unit
remotely").