Display control
10.13. Configure the inverter to work in self consumption mode
These inverters can work within a self consumption system. For this, you must configure the inverter for self
consumption system mode.
Access Main Menu > Advanced settings > Self consumption > Mode to select the self consumption mode.
There are different self consumption modes: No limitation (MPPT), Limited EMS manager and Self-limited CG
EM24.
No limitation (MPPT)
Self consumption mode without limits of injecting into the grid.
Limited EMS manager
Limited self consumption mode via the INGECON EMS Manager. For installations with
several inverters.
Self-limited CG EM24
Instantaneous self consumption mode limited by a wattmeter. For installations with a
single inverter.
10.14. Place the inverter in operating mode
To start the inverter in operating mode access Main menu > Start/Stop. This screen display's the inverter's current
status and enables, via a keypad
operating.
10.15. Place the inverter in stop mode
To place the inverter in stop mode access Main menu > Start/Stop. This screen display's the inverter's current
status and enables, via a keypad
to stopped.
10.16. See the daily power graph
The daily power graph displays the power generated throughout the current day. To see this graph, from the main
screen press
. Besides the daily power graph it lists the daily energy values (Ed), from the first connection of the
day to the time of consultation, total energy (Et) from the first inverter connection* and the instantaneous power (P).
* This historical meter returns to zero if reset to default settings.
10.17. See the energy graph for the last 24 days.
The energy graph of the last 24 days displays the energy generated throughout the last 24 days. To see this graph,
from the main screen press
(Ed), from the first connection of the day to the time of consultation, total energy (Et) from the first inverter
connection* and the instantaneous power (P).
ABE2011IQM01_C - Installation and Operation Manual
, changing the status. If the current status is stopped, press
, changing the status. If the current status is operating, press
2016-01-11
2016-01-11
2016-01-11
2016-01-11
. Besides the daily power graph of the last 24 days it lists the daily energy values
to change it to
10:17
10:17
10:17
10:17
Ingeteam
DE
EN
ES
FR
IT
PT
to change it
95