Decommissioning and disposal / Technical data
Size
Volume
0
0.15 l
I
0.35 l
II
1 l
II
1 l
III
2 l
IIII
4 l
* Compressed fluid
32
9
Decommissioning and disposal
IMPORTANT
• Depressurise the accumulator before proceeding.
• Clean all dirt and chemicals out of an accumulator that you
are decommissioning.
• Wear appropriate safety gear if metering hazardous or
unknown substances.
• Note relevant local directives when disposing of equipment.
10
Technical data
PS * V*
Connection
1.5
d 6, 8 or 12
3.5
d 12 – DN 8
10
d 16 – DN 10
10
d 20 – DN 15
20
G 1
1
/
– DN 20
4
1
40
G 1
/
– DN 25
2
Maximum operating pressure
Material version
PP
PVC
Material
version
PPE
PCB
PPE
PCB
PPE
PCB
PPE
PCB
PPE
PCB
PPE
PCB
Operating pressure
10 bar
6.6 bar
3.2 bar
10 bar
6 bar
1 bar
Order no.
1021157
1021120
243218
243203
243219
243204
243220
243205
243211
243207
243212
243208
Temperature
0 ... 20 °C
40 °C
60 °C
0 ... 20 °C
40 °C
60 °C
ProMinent
®