2. Change and activate code
a.) Display reads „Cod OFF":
- Using the torch trigger, switch to „Cod ON" (see Pt. 2b for
further instructions)
b.) Display reads „Cod ON":
- Use function button
CYC (cycle) indicates how often the unit can be switched on
without the code having to be entered
- Using the torch trigger, set the number of cycles
- Press function button
display
- Enter the new numerical code
- Enter 0-9/A-H using the torch trigger
- Confirm each numeral with function button
- Repeat this procedure twice, until all 3 digits of the new code
have been entered
- Press the torch trigger
- The display reads „Cod _-_"
- Re-enter the new code, for control purposes:
w set the desired numerals with dial I
w confirm each numeral with button
w repeat this procedure twice, until the code has been
entered
w the third time you confirm, the code is automatically
stored in the memory
Warning! If you enter the code incorrectly three times in a row
(ERR), the machine will automatically switch to „LOC". You
must switch the machine off and repeat the entire procedure!
- Machine is now ready for use
3. Deactivate code
- Display reads „Cod ON"
- Using the torch trigger, switch to „Cod OFF"
- Press button
or
to shift to „PRO"
- To deactivate the present code, press the torch trigger
-Machine is now ready for use
N.B.: From now on, the code is 321 again!
Machine start-up when codelock is activated:
- Switch on at the master switch
now asks you to enter the code number
- Enter the first numeral of the combination using dial I
- Confirm this numeral with function button
- Repeat this procedure twice more
- Machine is now ready for use
AC PARAMETERS LEVEL P3 (only on AC machines)
Use function button
or selector button
meters, and the torch trigger to change their values.
- ACF AC-frequency 40-100Hz (in "Electrode" and TIG modes)
- POS Positive half-wave (tri, SIN, rEC, OFF) only in TIG mode
- nEG Negative half-wave (tri, SIN, rEC, OFF) only in TIG mode
- PRO (Program): For storing the parameters that have been
set, by pressing the torch trigger.
[tri (=triangle), SIN (=sinus), rEC (=square wave)]
- SYn Synchronous function (ON/OFF)
to change to „CYC__?"
until „Cod ?---" appears on the
H
. The display („Cod _?_")
to select the para-
REMOTE CONTROL OPERATION GENERAL
Remote control units are intended for use in situations where the
welding parameters must be set directly from the welding work-
place. The remote control unit is connected electrically to the
power source by means of special cables 5 or 10 m in length.
The following types of remote control unit are available:
- TIG and manual electrode remote control unit (AC) . TR53mc
- Manual electrode and TIG remote control unit (DC) ....TPmc
- Manual electrode a. TIG remote control unit CEL (DC) TPmcCEL
- TIG pulsed-arc remote control unit (AC/DC) ............ TR50mc
- TIG spot-welding remote control unit (DC) ............... TR51mc
- TIG Remote-control pedal unit (AC/DC) ................... TR52mc
TR 53MC A.C. REMOTE CONTROL UNIT
- Special workplace remote control unit for TIG AC welding
- External setting facility for welding current I
Abb.11 AC-Fernregler TR 53mc
H
MAIN CURRENT DIAL I
- Continuous adjustment of the welding current
- LED indicator
BALANCE DIAL
- For influencing the positive and negative half-waves in the
manual-electrode and TIG AC~ ranges.
ADJUSTMENT DIAL for AC~ arc frequency (Hz)
- For changing the arc-concentration
Important! Use TR 53mc remote control unit for manual
electrode welding in the AC~ or DC ranges (function selector
switch
must be in pos.
HOTSTART TIME and ARCFORCE DYNAMIC are be gover-
ned by the values set on the main machine.
Connecting up the remote control unit
- Link the connecting-socket
socket on the remote control unit via the remote control cable.
- Plug in the connectors the right way round, and screw the swivel
nuts down as far as they will go.
- Shift the function selector switch
the operating mode required.
15
,
H
AC~ balance
AC~ frequency.
H
lights up after actuation of torch trigger
). HOTSTART CURRENT,
on the power source with the
into the correct position for