TABLE OF ALARM INDICATIONS
If the problem or fault noticed is not amongst thoselisted in the table,
consult the "Key to Alarms" tableprovided below.
The information provided below s intended to identifythe alarm signals
which appear on the display (A).
Important
Press button (D) to reset the alarm.
Alarm/Event
A01 - High temperature
alarm
(in conservation)
A02 - Low temperature
alarm
(in conservation)
A03 - Limit temperature
alarm
(in chilling/freezing)
A04 - Room probe alarm Room Probe interrupted
A05 - Evaporator probe
alarm
A06 - Condenser probe
alarm
A07 - Dirty condenser
alarm
A08 - Point needle probe
alarm
A09 - Underskin needle
probe alarm
A10 - External needle
IT
probe alarm
A11 - Electr.box probe
US
alarm
A12 - Electr.box over-
DE
temp. alarm
CAN
A13 - Open door alarm
ES
A14 - BlackOut alarm
A15 - High pressure
alarm
A16 - Low pressure
alarm
A17 - Compressor over-
load alarm
English
Cause
Room Temp above set value
Room Temp below set value
Cell or core temperature higher than
the set value
Evap Probe interrupted
Cond Probe interrupted
Condenser dirty
Needle Probe interrupted
Sub-dermis needle probe interrupted Qualified technician required
External needle probe interrupted
Electrical panel probe interrupted
Electrical panel temperature higher
than the set value
QC room door open
Door micro faulty
No power supply
Intervention by high pressure switch Qualified technician required
Intervention by low pressure switch Qualified technician required
Compressor thermal relay on
- 50 -
A
D
Remedy
If the temperature is not within the
specified range, apply to a qualified
technician
If the temperature is not within the
specified range, apply to a qualified
technician
If the temperature is not within the
specified range, apply to a qualified
technician
Qualified technician required
Qualified technician required
Qualified technician required
Clean the condenser
Qualified technician required
Qualified technician required
Qualified technician required
Qualified technician required
Close the door
Qualified technician required
When power is restored, check the
max. temperature reached inside the
room
Qualified technician required