Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CLEANING THE AIR CONDENSER
The air condenser should be kept clean to ensure the appliance's perfor-
mance and efficiency, as air should freely circulate inside the appliance.
The condenser should therefore be cleaned every 30 days, using non-
metal brushes to remove all dust and dirt from condenser blades.
– Access to the condenser is from the front.
– Unhook the front guard, pulling it towards you.
TROUBLESHOOTING
The appliance has been tested before being put into service.
The information provided below is intended to assist in the identification and correction
of any anomalies and malfunctions which might occur during use.
The user can solve some of these problems himself, but for others specific technical
knowledge or skill is required, and so they must only be carried out by qualified staff
with recognised experience acquired in the specific sector of operation.

Fault

The display board does
not switch on
Compressor failure
The compressor is work-
ing but the cabinet is not
cooling
Evaporator fans are not
working
The condenser fans do
not work
Lack of evaporator de-
frosting
English
FAULT
Remedy
No power supply
Blown fuse
Loosened connections
High and Low-pressure switch on
Clicker on
Contactor failure
Compressor thermal relay on
Frosted evaporator
No coolant inside the refrigerating
system
Delivery solenoid valve failure
Condenser dirty
Fan failure or short-circuit
Door micro failure
Faulty pressure switch
Faulty fan
Faulty pick-up condenser
Lack of consent from compressor
solenoid switch
Incorrect defrosting programming
- 49 -
Remedy
Check the connection to the power mains
Replace fuses (qualified technician)
Check connection fitting
Qualified technician required
Qualified technician required
Qualified technician required
Qualified technician required
Open the door and carry out the defrost
cycle
Qualified technician required
Qualified technician required
Clean the condenser
Qualified technician required
Qualified technician required
Qualified technician required
Qualified technician required
Qualified technician required
Qualified technician required
Check the defrosting cycle programming
Use and installation manual
6
IT
US
DE
CAN
ES

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

B151muB152muB1101su

Table des Matières