The cutting length can
be fine adjusted using
the tightening screw
on the electrode guide.
One round equals
1 mm. This adjustment
is also needed when
long electrode clamps
are used in the electrode holder, when grinding and
cutting short electrodes, to prevent the cutting disc
from damaging the electrode clamp.
For cutting off a
damaged tip on an
electrode, which has
not been grinded, use
one of the supplied tip
collectors instead of the
Pickup module. Choose
the tip collector suitable
for the diameter of the electrode.
9. Maintenance
The Green Pointer Pro Cut
must always have sufficient
grinding liquid, in order
to secure an optimum
collection of dust and
cooling of the grinding
process. A mark on the
glass frame of the
grinding chamber
indicate the correct
amount of grinding
liquid (measured while
the grinder is off). Check
amount of grinding liquid regularly and top up if
necessary. To ensure a long service life of the grinder
and the diamond discs use original original Green
Pointer Pro Cut grinding liquid.
Replaced the grinding fluid heavily contaminated with
dust.
Deposit grinding fluid and/or containers containing
dust in accordance with national regulations
depending on the grinding dust content. Please see
the data sheet of the selected electrodes.
Daily Inspection
In order to secure free movement of the angle
adjustment, move it all the way back and forward
every day. Not following this procedure, the machine
will gradually collect dust inside the grinding
chamber, and as a result, the angle setting will be
stuck and it is impossible to change the grinding disc.
Also make a daily check of the free movement of the
arm for cutting.
Monthly/1000 grind service
Clean the grinding chamber when the LED lights
yellow or at least once every month following these
steps:
1. Drain out the
grinding fluid
through the hose
into an empty
container.
2. Set the angle
adjustment to 90°
3. Remove the two
screws, the frame
and the inspection
cover
4. Wipe off the
grinding chamber
with a cloth or paper
towel. Eventually
remaining stuck
dust can carefully be
scraped off
5. Mount the inspection
cover and frame and
top up with grinding
liquid
6. Reset the service counter by turning on the grinder
and pressing and holding the pushbutton for 3
seconds.
If the grinding liquid does not come out of the hose,
it may be due to grinding dust inside the grinding
chamber blocking the hole. To get the grinding dust
away, press a little air or grinding fluid through the
hose, using the grinding fluid bottle.
Quarterly/5000 grind service
When the LED blinks yellow or at least once every
three months clean the inside of the grinding
chamber following these steps:
The power to the machine must be turned off – pull
out the plug.
1. Drain out the grinding fluid through the hose into
an empty container.
2. Set the angle adjustment to 90°.
3. Remove the dust collector under the grinding
chamber.
4. Place a support under the motor housing, ~20mm
tall. Remove the three torx screws on the back of
the grinding chamber and the two bolts under the
table. Now you can remove the grinding chamber
from the motor housing.
5. Clean out the grinding dust inside the grinding
chamber. Dismantle the angle adjust unit if
necessary. Make sure the angle adjust unit can
slide smoothly all the way back and forth.
6. When assembling the parts add bearing grease to
all moving parts, screws and gaskets except for the
Inspection cover mounting.
7. Check the O-ring on the backplate before
mounting the grinding chamber.
13