Set the following values using the "PARAMETERS" pushbutton on the main menu:
Preflow. Adjustment ranges from 0.1 to 10 seconds Turn knob I to
change the value, press to confirm.
Postflow. Adjustment ranges from 0.1 to 25 seconds Turn knob I to
change the value, press to confirm.
Gas Flow. Active only with Kit 436. Adjustment ranges from 5 to 30 l/
min. Turn knob I to change the value, press to confirm.
Wire Weight. Welding wire consumption is shown in grams per metre
to calculate spool consumption. The value must be preset. Use the
default value if the weight of the wire is not known.
Soft Start. The adjustment can vary from 10 to 100%. This is the wire
feed speed expressed as a percentage of the speed set for welding,
before the wire touches the workpiece to be welded. This adjustment
is important for achieving effective start-ups. Press AUTO to call up
the factory settings.
Burnback. The adjustment can vary from -125 to +125 ms. Its purpose
is to adjust the length of wire emerging from the gas nozzle after
welding. A positive figure means more wire has been burnt and the
amount sticking out is shorter. Press 0 to call up the factory settings.