MANUAL MANOEUVRE WITH THE MOTOR RELEASED
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Manual release is to be carried out with the motor Stopped. To release the gate use
the manual release key supplied with the unit. The key should be kept in an easily
accessible place.
SCREW OPERATED MANUAL RELEASE
SL1524SB
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
To release the unit (fig. 8a)
1. Lower the lock protection "A" on the
release knob, insert the key "B" and
rotate it through 180 degrees clockwise.
The knob is now free and can be rotated.
2. Rotate the knob "C" clockwise until
reaches its travel limit. The geared motor
is now released and the gate can be
moved manually.
Attention! Do not force the knob to
exceed the travel limit.
To relock the unit (fig. 8a)
1. Rotate the knob "D" anticlockwise until
it blocks completely.
Attention! Do not force the knob to
exceed the travel limit.
2. Rotate the key anticlockwise and posi-
Drawing number :
tion the lock protection.
Product Code :
The geared motor is now locked and the
Draft :
gate may be used normally.
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Once the system is running normally
store the key in a safe place.
Drawing number :
2-POSITION MANUAL RELEASE
Product Code :
SL1524
Drawing number :
Draft :
P.J.Heath
Product Code :
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
To release the unit (fig. 8b)
Draft :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
1. Rotate the lock protection disk on the
release knob, insert the key and rotate
it half a turn anticlockwise. The knob is
now free and can be released.
2. Rotate the knob through 90° clockwise.
Drawing number :
The gears are now released and the gate
Product Code :
can be moved manually.
Draft :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
To relock the unit (fig. 8b)
1. Rotate the handle anticlockwise and
move it back to the blocked position.
2. Rearm the gears:
- electrically by giving an opening or closing command;
- by slightly moving the gate
3. Rotate the key clockwise and relock the handle.
Once the system has been reset store the key in a safe place.
ghts reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Attention! Never use the manual release mechanism while the gate is in
operation. If you release the gate and then give a movement command
the following symbol will appear on the display
9
A
A
C
Description :
Sblocco nuovo "A"
DM0801
SL1524SB
SL1524SB
P.J.Heath
Date :
13-11-2008
D
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Description :
Sblocco nuovo "B"
DM0802
SL1524SB
SL1524SB
Description :
Sblocco nuovo "C"
DM0803
Date :
13-11-2008
SL1524SB
SL1524SB
Date :
13-11-2008
Description :
Sblocco nuovo "D"
DM0804
SL1524SB
SL1524SB
Date :
13-11-2008
SCALA: 1:2
Description :
Drawing number :
DI0242
Sblocco motore
Product Code :
SL1524
Draft :
P.J.Heath
Date :
07-02-2002
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Access to the electronic card
Attention! Before opening the cover make
sure that the power has been switched off
at the mains.
To access the motor loosen the two
screws "A" positioned on either end of the
cover as indicated in figure 9.

ELECTRONIC PROGRAMMER

Electronic programmer for a dc motor with an incorporated radio receiver card, which
allows the memorisation of 300 user codes (see "remote control" page 20). The
"rolling code" type decoder uses 433.92 MHz series transmitters.
The motor rotation speed is electronically controlled, starting slowly and increasing
in speed; the speed is reduced as it nears the travel limit so as to enable a controlled
smooth stop.
8
a
Programming is carried out using one button and allows you to set the system, the
current sensor and the entire gate travel distance while the logic carries out position
control using an encoder.
The intervention of the anticrush/antidrag sensor during the closing and opening
stages causes a brief (10 cm) travel direction inversion then a block.
180°
B
5 - 6 turns
5 - 6 turns
All rights reserved. Unauthorised copying or use of the information contained i
8
b
Mains power supply connection
Prodotti Technocity
.
• Connect the control and security device wires.
• Run the mains power supply through the cable clamp located on the bottom right
of the main circuit board and to the separate 3-way terminal board:
- connect the neutral to binding post N
- connect the earth to binding post
- connect the live to binding post L
15
IMPORTANT REMARKS
• After having installed the device, and before powering up the program-
mer, release the gate (manual release mechanism) and move it manually,
checking that it moves smoothly and has no unusual points of resistance.
• The programmer can activate the motor automatically. This is indicated
by the warning lights pre-flashing for 10 seconds, and by the symbol
appearing on the display ("automatic repositioning" on page 19).
• The programmer is fitted with an electrical input monitoring system,
which is used to block the motor in emergency conditions; however
this system is not active during the following stages:
- during the first 5 second of an opening stage starting from completely
closed
- during the first 2 seconds of all other movement stages
- when the battery undercharged
Do not therefore attempt to physically block the door during these
stages, otherwise you may risk blowing the motor circuit protection
fuse "F1".
• If you need to check the status of the fuse "F2", disconnect the power
supply to the programmer; reconnect it only after having re-inserted
the fuse.
• The presence of the electrical input monitoring system does not exclude
the need to install photoelectric cells or other safety devices which
are foreseen by the local standards and regulations in force.
• The geared motor unit has been assembled in the factory to be fitted
to the left side of the gate. Read the paragraph "instructions for
positioning the unit".
• For the correct operation of the programmer the incorporated batteries
must be in good condition: the programmer will lose the position of
the gate in case of blackouts when the batteries are flat, the alarm
will sound and automatic repositioning will take place .
Check the good working order of the batteries every six months (see
page 21 "Battery check").
• Before connecting the appliance make sure that the voltage and
frequency rated on the data plate conform to those of the mains
supply.
• An all pole trip switch with at least 3 mm between the contacts must
be installed between the unit and the mains supply.
• Don't use cables with aluminium conductors; don't solder the ends
of cables which are to be inserted into the binding posts; use cables
marked T min 85°C and resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both the
wire and the insulating sheath are tightly fastened (a plastic jubilee
clip is sufficient).