Dispensing coffee with the Dispensing Lever
The coffee dispensing lever allows the user to personalise the duration of the individual dispensing phases.
The duration of the infusion cycle plays a fundamental role in creating the perfect espresso. To that end, the recommended
time for an Italian espresso is between 3 and 7 seconds.
Note: the maximum duration for the infusion phase is 10 seconds, after that time the dispensing phase will start in any
case.
1
Idle
Infusion
Move the dispensing lever
from the "Idle" position to the
"Infusion" position.
5
Dispensing
Idle
02_E71_1USO_1646.indd 16
2
T h e
i n f u s i o n
p h a s e
starts, represented on the
touchscreen display for the
group with the symbol
with the relative duration.
The symbol
indicates
the position of the lever.
When the desired dose
is achieved, move the
dispensing lever from the
"Dispensing" position to the
"Idle" position.
3
Infusion
Dispensing
Move the dispensing lever
from the "Infusion" position
to the "Dispensing" position.
6
Before returning to the standby phase, the touchscreen
will show the following parameters for a few seconds: total
dispensing duration and duration of infusion phase.
16 EN
4
The dispensing phase starts,
represented by the symbol
with the relative
duration.
The symbol
indicates
the position of the lever.
17/11/2016 13:41:07