ENGLISH
Indication of the operating status
When the circulator is operating, the LED (B) is green. The four
yellow LED (C) indicate the electrical energy consumption (P1) as
shown in the following table.
LED status
Green LED on +
1 yellow LED on
Green LED on +
2 yellow LEDs on
Green LED on +
3 yellow LEDs on
Green LED on +
4 yellow LEDs on
(*)
For the power (P1) absorbed by a single circulator, refer to
the "Technical Data" table.
Indication of the alarm status
If the circulator has detected one or more alarms the bi-colour LED
(B) is red. The four yellow LEDs (C) indicate the type of alarm as
shown in the following table.
ALARM de-
LED status
scription
Red LED
on +
The motor shaft
1 yellow LED
is blocked
on (LED 5)
Red LED
on +
Low input
1 yellow LED
voltage
on (LED 4)
Red LED
Problem with
on +
the electrical
1 yellow LED
supply or else
on (LED 3)
circulator faulty
When there are several alarms, the circulator will only
display the alarm with the highest priority.
Displaying the active settings
With the circulator powered up, briefl y press the key (A) to display
the active confi guration of the circulator. The LEDs indicate the ac-
tive settings.
No changes to the confi guration of the circulator can be made in
this phase. Two seconds after the key (A) has been pressed, the
user interface returns to the normal display of the operating status.
Key lock function
The key lock function prevents any accidental modifi cation of the
settings or the improper use of the circulator.
When the key lock function is activated, prolonged pressure of the
key (A) is inhibited. This prevents the user entering the section for
setting the circulator's operating modes.
The key lock function can be enabled/disabled by pressing the key
(A) for more than 10 seconds. During this passage all the LEDs (C)
blink for 1 second.
> 10 s
Changing the operating mode
When operating normally the circulator works with factory settings
or the last setting carried out.
To change the confi guration:
Make sure that the key lock function is disabled
22
Consump-
Status
tion in % of
CIRCULATOR
P1 MAX (*)
Operating at the
0―25
minimum
Operating at the
25―50
minimum-medium
Operating at the
50―75
medium-maximum
Operating at the
100
maximum
Status
Possible
CIRCULA-
REMEDY
TOR
Start attempt
Wait or
every 1.5
unblock the
seconds
motor shaft
Only a warn-
ing. The cir-
Check the
culator keeps
input voltage
operating
Check the
The circu-
power sup-
lator has
ply or else
stopped
replace the
circulator
Press the key (A) for more than 2 seconds until the LEDs start to
blink. By briefl y pressing the key (A), within 10 seconds the user
interface will pass to a display of the successive settings. The vari-
ous available settings will appear in a cyclical sequence
If the key (A) is not pressed, the last setting selected will be saved.
visualizzazione
operating status
stato di
display
funzionamento
2 s
visualizzazione
Setting
impostazione
display
By pressing the key (A) it will be possible once again to pass to
"displaying the active settings" and check that the LEDs (B) and (C)
indicate, for 2 seconds, the last setting carried out
If the key (A) is not pressed for more than 2 seconds, the user in-
terface will pass to "displaying the operating status".
The available settings are shown below together with the relative
representation of the LEDs (B) and (C).
7 m
1
6 m
2 (*)
5 m
3
4 m
4
IMPORTANT
Where the curves were set 3 ( 5 meters ) or 4 ( 4 meters ) is
necessary to replace the by-pass with the one supplied.
Setting
> 2 s
impostazione
10 s
LED 1
LED 2
LED 3
LED 4
LED 1
LED 2
LED 3
LED 4
green
yellow
yellow
yellow
rosso
giallo
giallo
giallo
(*) valore settato da fabbrica
Factory settings
x
LED 5
LED 5
yellow
giallo