Safety conditions

Note
Incorrect handling can lead to malfunctioning.
• Make sure that the specifications in this chapter are always observed.
• Compare the maximum values in these operating instructions with your actual application
(e.g. pressures, temperatures).
• Also observe national regulations and the specifications of standards EN ISO 4414, EN 574 and
EN ISO 13849-1.
• Use a service unit of the MS or D-series from Festo for preparing the compressed air (
• Take suitable measures to ensure the minimum pressure of 4 bar necessary for operation.
A pressure sequence valve of type VD-3-PK-3, for example, is suitable here (
• Remove the packaging except for the adhesive labels on the compressed air supply ports (to
prevent dirt).
• Observe local regulations when disposing of the product and its packaging.
• Use the product in its original status, without any unauthorised
product modifications. The individual components are fixed with
screw locking agent (
Fig. 3).
4.1

Areas of application and approval by authorities

The product is a safety component as defined in the Machinery Directive 2006/42/EC and carries the CE
mark. Standards and test values, which the product complies with and fulfils, can be found in the
Technical data section (
chapter 12).
The product-relevant EU directive can be found in the declaration of conformity.
Certificates and the declaration of conformity for this product can be found at www.festo.com.
16
130
Fig. 2).
Fig. 2).
Fig. 3
Festo – ZSB-1/8-B – 1202NH English
ZSB-1/8-B
5

Installation

5.1

Mechanical assembly

1. Place the product so that the filter for the breathing opening 4 is not covered.
2. Fasten the product with two M5 screws via the through holes 6 or with two M5 screws via the
fastening thread.
3. Install two 3/2-way push-button valves (
Fig. 2).
Caution
Any attempt to actuate the push-button valves with only one hand or with an elbow, a
knee or a foot will impede the safety function (
• Make sure the requirements for setting up two-hand push-button switching circuits
as per EN 574 are observed, e.g. by specifying the minimum distance between the
push-buttons.
• If necessary, take into account existing C-standards for your type of machine.
• Implement the measures as per EN 574.
Fig. 4
5.2

Pneumatic fitting

1. Remove the transport covers on the compressed air connections.
2. Connect the tubing with the specified components (
Note
The product will function as intended providing it is set up correctly and if the
exhausting is correct.
• Use the same lengths of tubing between the push-button valves and the two-hand
control unit.
• Secure the hoses to the system to prevent them from moving in an uncontrolled
manner.
• Use only 3/2-way push-button valves.
• The outlet ports 3 must remain open to allow venting of the push-button valves.
Use a suitable silencer if required.
• If required, use a suitable silencer at outlet port 3 of the control block for two-hand
start (
www.festo.com/catalogue/zsb).
• Replace contaminated silencers if necessary.
Festo – ZSB-1/8-B – 1202NH English
Fig. 4).
Tab. 1).