OP1 = output 1
OP2 = output 2
OP3 = output 3
OP4 = output 4
With these outputs, a number of different functions can be implemented, for
example:
Triggering of signaling devices
Switching of lighting, fans, etc.
The outputs can also be controlled remotely.
Output types
OFF: The output is permanently disabled (default).
Message Waiting
and deactivated when the message has been played once.
Remote Access: The output is activated upon remote access via
telephone. The output is reset when the remote dial-in is finished.
High Temperature: The output is activated when the preset tempera-
ture threshold is exceeded. The output is deactivated when the tem-
perature falls below the defined threshold again.
See setting in "System Settings Alarm Levels High Temperature"
Low Temperature: The output is activated when the preset tempera-
ture threshold is undershot. The output is deactivated when the tem-
perature rises above the defined threshold again.
See setting in "System Settings Alarm Levels Low Temperature"
Listen Active: This output is activated when listen mode is started.
See also "Operation Remote Access Functions in Remote Ac-
cess Mode"
Speech Active: This output is activated when speech mode is activat-
ed.
See also "Operation Remote Access Functions in Remote Ac-
cess Mode"
Phone Line Fault: The output is activated when a fault occurs on the
telephone connection.
The connected telephone line is disconnected
No voltage on the connected telephone line
The device requires about 50 s to register this fault.
PSTN In Use: The output is activated when the device is active on the
analog telephone line.
GSM In Use: The output is activated when the device is active on the
GSM cellular network.
Call Active: The output is activated when the device triggers and a
dialing procedure has been started. The output is deactivated after the
device has called all contacts or if the call is canceled.
:
The output is activated when a message is waiting
32 UK