Text Message; Inbox; System Settings; Trigger Polarity - Abus AZWG10020 Instructions D'installation Et De Service

Transmetteur téléphonique gsm/rtc
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 109
playing voice messages. Messages should be recorded so that they reflect
the on-site status. For example, if an alarm control panel output is to switch
due to a fire alarm, then the device control should trigger a message stating
that a fire has broken out at the location.
At the end of the message, it is recommended that you record
instructions stating that the message must be acknowledged by
pressing 8 on the telephone. Otherwise, the next programmed
telephone number is dialed.
12.2.2

Text Message

The device can send text messages using the default SMS service (Short
Message Service) to SMS-enabled end devices (mobile phones or landline
phones).
The device can manage eight alarm messages (SMS) of up to 40 charac-
ters.
The "location message" (location text) with the time and date of the device is
transferred automatically when the device sends a text message. A "location
message" should usually give details about the protected area or the de-
vice's installation location (such as name and address).
12.2.3

Inbox

The device is able to receive text messages. For example, these can be
reminders from your service provider that your balance is low (if you use a
"pay as you go" or "prepaid" SIM card ) or other incoming SMS messages
sent to the GSM number of the device. These SMS messages can also be
forwarded (see menu item "Call Routing  Text Forward")
Incoming SMS messages are stored on the SIM card. How many SMS
messages can be stored depends on the capacity of the SIM card.
The device cannot receive SMS messages via the analog tele-
phone connection.
The inbox has two sub-menu items:
View Messages
Delete Inbox
Once you have read a message, you should delete it.

12.3 System settings

Various system settings relating to how the device works can be made in the
system settings.
12.3.1

Trigger Polarity

The device can be triggered by negative (0 V DC; default) or positive (+12 V
DC nominal, +10.5 to +24 V) polarity. This setting applies globally for all
eight inputs (A-H TRIG).