Install the corresponding connection collar that
was supplied on the outlet that you want to use.
Sealant and materials are supplied.
Connecting to the rear
1. Apply supplied fibre glass sealing tape of 10x3mm
to the contact surface of the connection collar.
2. Install the connection collar to the back wall with
the materials.
Connect to top
1. Remove the top plate.
The top plate can be taken off the appliance
just like that.
2. Remove the decorative cover (12) from the top
plate.
3. Remove the cover (10) from the inner top plate.
4. Apply sealing tape measuring 10 x 3mm to the
contact surface of the connection collar.
5. Install the connection collar to the inner top plate
with the materials.
Subject to change because of technical improvements
6. Install the cover to the back wall with the
materials.
Preparing the connection to
the outside air
If the appliance is installed in a room without sufficient
ventilation, you can install the connecting kit on the
appliance (supplied with the appliance) for the supply
of outside air. Some of the air inlets on the appliance
must then be plugged with the blanking material
provided.
The air supply tube has a diameter of 100mm. If the
tube is smooth, it may be no longer than 12m. If
accessories such as bends are used, the maximum
length (12 m) must be reduced by 1 m for each
accessory used.
Outside air connection via the floor
1. Make an opening in the floor (see Appendix 2,
Measurements, for the correct position of the
opening).
2. Hermetically close the air supply tube at the floor.
9