Appendix 1: Technical data
Model
Nominal output
Flue connection (diameter)
Weight
Recommended fuel
Fuel property, max. length
Mass flow of flue gases
Flue gas temperature measured in the
measurement section
Temperature measured downstream from the flue
spigot
Minimum draught
CO emission (13%O2)
NOx emission (13% O2)
CnHm emission (13%O2)
Particulate emission
Particulate emission in accordance with NS3058-
NS3059
Efficiency
Subject to change because of technical improvements
Vintage 50 Vintage 35 Vintage 30
9 kW
7 kW
150 mm
150 mm
+/- 155 kg
+/- 125 kg
Wood
Wood
50 cm
35 cm
6.4 g/s
4.9 g/s
232
251
328
298
12 Pa
12 Pa
0,10 %
0,05 %
112 mg/Nm³
84 mg/Nm³
96 mg/Nm³
82 mg/Nm³
16.4
27.1 mg/Nm³
mg/Nm³
4.94 gr/kg
4,99 gr/kg
84,2 %
83 %
5 kW
150 mm
+/- 95 kg
Wood
30 cm
4.2 g/s
244
305
12 Pa
0,05 %
127 mg/Nm³
48 mg/Nm³
6.0 mg/Nm³
1.38 gr/kg
80,4 %
19