k) Setting the Locking Time for Output #1
Here, you can set a specific period during which the code lock for output #1 does not accept any
inputs (e.g. between 10 PM and 6 PM). The input must be made in 24h format ("00:00" to "23:59").
To set a locking time, you need to programme the time first, see chapter 11. j).
An externally connected door opener button will work independently of whether a locking
time is entered or not.
During the locking time, the left LED is lit permanently red (the LED briefly flashes
orange as usual, however, to display regular operation).
Proceed as follows to set the locking time:
• The code lock must be in programming mode; see chapter 11. b).
• Enter the programming code
• Enter the hours (e.g.
• Enter the hours (e.g.
The two times must differ; otherwise, the code lock will emit an error message.
• Confirm your input with the
• The code lock emits two beeps; programming is saved.
1. Example: Programming a locking time from 10 PM to 6 AM
(a)
(b)
(a) Start programming for the locking time
(b) Set the start of the locking time to 22:00
(c) Set the end of the locking time to 06:00
(d) Save programming (code lock emits two beeps)
100
.
) and the minutes (e.g.
) and the minutes (e.g.
button.
(c)
(d)
) for the start of the locking time.
) for the end of the locking time.