3 Fonctionnement de la face avant
3.1 Menu Options
Tous les réglages et les paramètres peuvent être configurés à partir du menu système de l'alimentation.
Pour accéder au menu appuyez sur la touche
comme suit :
1. PARAMETRES SYSTEME
REMOTE(USB,ETHERNET,GPIB,RS232 (optional))
GPIB ADDR(1-30)
LOCK (ON, OFF)
IP CONFIG(STATIC)
IP ADDRESS (xxx.xxx.xxx.xxx, where x = 0 - 9)
BEEP (ON, OFF)
LCD BACKLIT (ALWAYS ON, 1,5,10,30 MINS OFF)
RECALL DEFAULT(NO,YES)
POWER ON STATE (OFF,LAST)
OUTPUT MODE (MULTI,SINGLE)*
TRACKING MODE (ON,OFF)*
EXTERN CONTROL (VOLT,RES,OFF) (optional)
EXTERN LEVEL (5V,10V) (optional)
EXTERN TRIG (ON,OFF) (optional)
2. OUTPUT SETTING
1. VOLTAGE LIMIT SETTING
VOLT LIMIT MAX (0 – Max. Voltage)
VOLT LIMIT MIN (0 – Max. Voltage)
2. COURRANT CURRENT LIMIT SETTING
CURR LIMIT MAX (0 – Max. Current)
CURR LIMIT MIN (0 – Max. Current)
3. VOLT SLEWRATE SETTING
V SLEWRATE
4. CURR SLEWRATE SETTING
I SLEWRATE
5. MEASURE AVERAGE(1-10)
6. LED MODE SETTING
LED MODE (ON,OFF)
Low Current Mode (ON,OFF)**
3. PROTECTION
1. OVP SETTING
OVP (ON,OFF)
SET (0 – Max. Voltage)
2. OCP SETTING
OCP (ON,OFF)
SET (0 – Max. Current)
4. MEMORY SETTING(0-9)
5. PROGRAM MODE
6. TIMER FUNCTION
TIMER (ON,OFF)
TIME (hr:min:sec)
7. CALIBRATION
8. INFORMATION
9. CHAIN SETTING (optional)
CHAIN ON/OFF (ON,OFF)
CHAIN ADDRESS(1-31)
* Modèles 9173 et 9174 à canal double uniquement
** Modèles 9184 et 9185 uniquement
Menu
. Le menu est divisé en 8 catégories et organisé
17