Fault
Pressure drops below
set level
Setting pressure cannot
Leak at diaphragm (5)
Leak at adjusting screw (13)
Materials
Item*
2
Spring dome
4
Thrust washer
8
Compression spring
7
Spring plate
5
Formed diaphragm
3
Separating disc
10
Piston
15
Valve seat seal
22
Connection seal
1
Valve body
12
Connecting screw
1
2
PTFE with carbon;
PTFE pure white,
* For item numbers see Fig. 4 and 5
®
Viton
is a registered trademark of DuPont Dow Elastomers.
ProMinent
®
Troubleshooting / Technical Data
7

Troubleshooting

(see Fig. 4)
Cause
Valve seat seal (15)
or
valve seat defective
Diaphragm (5) defective
Valve installed wrong way
Contact pressure diaphragm
tension too low
Diaphragm (5) defective
8

Technical Data

Storage and transport temperature:
The backpressure valve must not be exposed to frost!
Combination options:
The backpressure valve can be used together with the metering
pumps G5, Vario, Sigma, Hydro, Meta, Makro TZ and Makro/ 5.
PP1
PC1
PP-GFK
PP-GFK
PP
PP
Galvanized Galvanized Galvanized
steel
steel
PP
PP
EPDM/PTFE laminated
PP
PVC
PP
PVC
EPDM
FPM
®
EPDM
Viton
A
PP
PVC
V2A
V2A
3
envelope ring PTFE/Viton
Corrective measures
Replace valve seat seal (15)
Consult ProMinent
Replace diaphragm (5)
(Chapter 6)
Turn valve
(observe direction arrow)
Retighten screws (12)
(approx. 6 Nm)
Replace diaphragm (5):
(Chapter 6)
PV1
TT1
PP-GFK
PP-GFK
PP
PP
Galvanized
steel
steel
PP
PP
2
PVDF
PTFE
2
2
PTFE
PTFE
FPM/PTFE
FPM/PTFE
®
3
Viton
A
PTFE
1
PVDF
PFTE
V2A
V2A
®
SS1
PP-GFK
PP
Galvanized
steel
PP
2
PTFE
2
PTFE
FPM/PTFE
3
PTFE
1.4571
V2A
23