Description of controls

Safety

Controls and
connections
Fig.3
(1) Mains switch
(2) Control LED ... glows when the mains switch (1) is in the "I" position and the mains
(3) Output current adjusting dial
(4) Malfunction indicator ... lights up when the machine is thermally overloaded (i.e.
(5)
(6)
(7) External control connection socket ... for specifying the output-voltage command
(8) Operating-mode button / indicators ... On the TP 1500 RC HD power source,
(9) Dust filter (not illustrated) ... is located in the fan air-intake zone
Warning! Operating the machine incorrectly can cause serious injury and
damage. Do not use the functions described here until you have read and com-
pletely understood the whole of the "Operating Instructions" manual.
(6)
(5)
Front view of TP 1500 RC HD
plug is plugged into the mains
when it overheats)
current socket with bayonet latch ... for connecting up the "plus" cable for
preheating the welding wire
current socket with bayonet latch ... for connecting up the "minus" cable for
preheating the welding wire
value by way of an analogue signal
these are not selectable
Note! We recommend that the power source should ONLY be used with a dust
filter.
(7)
(4)
(1)
(9)
Fig.4
Control panel
5
(3)
(2)
(8)