Replacing the Light Bulb
1. Turn off the power switch and unplug the machine.
2. Loosen the face plate set screw, and remove the
face plate.
© Face plate
(2) Set screw
To remove:
Push and twist to the left.
To attach:
Push and twist to the right.
Reattach the face plate, and retighten the face plate
set screw.
(3) Light bulb
(4) To remove
(6) To attach
Note:
* The machine is designed to use a 15 WATT
maximum light bulb.
Cleaning the Feed Dog
1. Turn off the power switch and unplug the
machine.
2. Open the looper cover and side cover.
. Remove the needles and presser foot.
4. Remove the needle plate set screw, and remove
the needle plate.
(D Needle plate
(2) Needle plate set screw
ie)
5. Brush out the lint around the feed dogs to the
front by using the lint brush or use a vacuum
cleaner.
6. Reattach the needle plate, presser foot and
needles.
Close the looper cover and side cover.
C) Feed dog