13
ANNEXE
Table 94 : Example: sWA TSCRole
<STX>sWA{SPC}TSCRole<ETX>
CoLa A
02
73 57 41
20
54 53 43 52 6F 6C 65
CoLa B 02 02 02 02 00 00 00 0C
13.5.1.4.4.2
The data format in the telegram is: +2009{SPC}+7{SPC}+22{SPC}+12{SPC}+0{SPC}+0{SPC}+0.
The numbers represent year, month, day, hour, minute, second, microsecond.
If plus is used up-front the data it is interpreted as an integer decimal number, without the plus it's the scanner
reads the data as hex format.
The answer is always in ASCII format.
NOTE
Does only work if NTP-Client is not active.
NOTE
There is no real time clock inside the device. When the scanner is switched off and after a reboot, the time has to
be set again. Therefore, it is recommended to use NTP setting.
Table 95 : Telegram structure: sMN LSPsetdatetime
Telegram structure: sMN LSPsetdatetime
(User level 'Authorized client' required)
Telegram
Description
part
Command
Method
type
Command Set time stamp
Year
Month
Day
Hour
Minute
Second
Microsec‐
ond
84
N O T I C E D ' I N S T R U C T I O N | picoScan120
03
73 57 41
20
54 53 43 52 6F 6C 65
Set time stamp [sMN LSPsetdatetime]
Variable
Length
String
3
String
14
Uint_16
2
Uint_8
1
Uint_8
1
Uint_8
1
Uint_8
1
Uint_8
1
Uint_32
4
20 15
Additional details
Values CoLa A
sMN
LSPsetdatetime 4C 53 50 73
+1970d ...
+2099d
(07B2h ...
0833h)
+1d ... +12d
(01h ... 0Ch)
+1d ... +31d
(01h ... 1Fh)
+0d ... +23d
(00h ... 17h)
+0d ... +59d
(00h ... 3Bh)
+0d ... +59d
(00h ... 3Bh)
+0d ...
+999999d
(00000000h ...
000F423Fh)
Values CoLa B
(ASCII)
(Binary)
73 4D 4E
65 74 64 61
74 65 74 69
6D 65
07 B2
...
08 33
01
...
0C
00
...
1F
00
...
17
00
...
3B
00
...
3B
00 00 00 00
...
00 0F 42 3F
8029549/0000/2024-10-17 | SICK
Subject to change without notice