Télécharger Imprimer la page

SICK picoScan120 Notice D'instruction page 74

Publicité

13
ANNEXE
Table 62 : Example: sAN Run
<STX>sAN{SPC}Run{SPC}1<ETX>
CoLa A
02
73 41 4E
20
52 75 6E
CoLa B 02 02 02 02 00 00 00 09
13.5.1.4.2.12
This command includes saving all parameters.
Table 63 : Telegram structure: sMN mSCreboot
Telegram structure: sMN mSCreboot
(User level 'Authorized client' required)
Telegram
Description
part
Command
Method
type
Command Reboot device
Table 64 : Example: sMN mSCreboot
<STX>sMN{SPC}mSCreboot<ETX>
<STX>sMN mSCreboot<ETX>
CoLa A
sMN mSCreboot
02 73 4D 4E 20 6D 53 43 72 65 62 6F 6F 74 03
02 02 02 02 00 00 00 0D
CoLa B
73 4D 4E 20 6D 53 43 72 65 62 6F 6F 74
Table 65 : Telegram structure: sAN mSCreboot
Telegram structure: sAN mSCreboot
Telegram
Description
part
Command
Answer
type
Command Reboot device
Table 66 : Example: sAN mSCreboot
<STX>sAN{SPC}mSCreboot<ETX>
CoLa A
02
73 41 4E
20
6D 53 43 72 65 62 6F 6F 74
CoLa B 02 02 02 02 00 00 00 0E
13.5.1.4.3
Measurement output telegram
13.5.1.4.3.1
Asking the device for the measurement values of the last valid scan. The device will respond, even if currently no
measurement data is created (e.g. due to standby or log in).
NOTE
During the bootup phase of the device, there will be no data telegram or answer from the device.
74
N O T I C E D ' I N S T R U C T I O N | picoScan120
20
31
03
73 41 4E
20
52 75 6E
Reboot device [sMN mSCreboot]
Variable Length
String
3
String
9
73 4D 4E
20
6D 53 43 72 65 62 6F 6F 74
Variable
Length
String
3
String
9
03
73 41 4E
20
6D 53 43 72 65 62 6F 6F 74
Poll one telegram [sRN LMDscandata]
20
01
34
Additional details
2C
Additional details
20 00
Values CoLa A
Values CoLa B
(ASCII)
(Binary)
sMN
73 4D 4E
mSCreboot
6D 53 43 72
65 62 6F 6F 74
Values CoLa A
Values CoLa B
(ASCII)
(Binary)
sAN
73 41 4E
mSCreboot
6D 53 43 72
65 62 6F 6F 74
8029549/0000/2024-10-17 | SICK
Subject to change without notice

Publicité