5.1
Shielding connection
5.2
Connecting device electrically
5.3
Safe motor feedback system signals
5.4
STL70S / M12, 8-pin
8028430/2023-04-19 | SICK
Subject to change without notice
NOTE
Select the area of application so that inductive or capacitative faults cannot affect the
sensor or its connecting cable.
NOTE
A suitable encoder shield connection to the ground or to the motor shield is required for
smooth operation.
NOTE
Install the cable with strain relief. If necessary, provide a drag chain or protective hose.
Connect directly via M12 round screw system or cable connection.
The rotatable male connector / cable connection is intended only for aligning
the male connector / cable connection during mounting, not for permanent move‐
ment.
The enclosure rating for the connector outlet can only be achieved with the mating
connector screwed into place.
Tightening torque for the mating connector at an M12 male connector outlet: 1.0 Nm
The safe motor feedback system has the following signals:
HIPERFACE
®
interface:
US supply voltage; the supply voltage is between +7 V and +12 V, the recom‐
mended supply voltage is +8 V.
GND - ground connection; electrically isolated from the housing. The voltage drawn
is US.
+ SIN process data channel; sine signal of 1 Vpp with a static offset of REFSIN.
REFSIN process data channel; static voltage of +2.5 V, reference voltage for +SIN.
+ COS process data channel; cosine signal of 1 Vpp with a static offset of REFCOS.
REFCIS process data channel; static voltage of +2.5 V, reference voltage for +COS.
Data ± – RS485 parameter channel: negative/positive data signal; the parameter
channel is an asynchronous, half-duplex interface which physically conforms to
the EIA RS485 specification. For this, data can be requested from the safe motor
feedback system through different commands; this also makes it possible to
write user-specific data such as position offset to the E2PROM of the safe motor
feedback system.