DISPLAY WARNINGS KEY
C<n>
Wired safety device active
r7
R7 safety device (sensitive edge) active
C0
Total stop active
P<n>
RIO safety device active
RIO ED T2] and [RIO PH T1 - RIO PH T2]
OP.
Passage fully open
CL.
Passage fully closed
Error messages
E4
Service test failure error
E9
Consecutive obstacles detected during closing
E13
Limit switch input error or both limit switches open
E15
Incompatible transmitter error
E17
Wireless system communication error
E18
Wireless system not confi gured error
The <n> value is associated with the selected parameter for the functions.
The <n> value is associated with the selected parameter for the functions [RIO ED T1 -