F2 CX input
F3 Input C1
Safety devices
F5
test
F6 Hold-to-run
F7 Command 2-7
Obstacle with
F9
motor stopped
OFF (Default)
C1 = Reopen while closing
(photocells)
C3 = Partial stop Only with [F19 -
Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive
edges). Inhibited in the fully closed
position.
r7 = Reopen while closing (sensitive
edges with 8K2 resistor). Inhibited in
the fully closed position.
OFF
C1 = Reopen while closing
(photocells)
OFF (Default)
1 = CX
2 = C1
3 = CX+C1
OFF (Default)
ON
0 = Step-by-step (default) - The fi rst
command is to open and the second
to close.
1 = Sequential - The fi rst command
is to open, the second to STOP, the
third to close and the fourth to STOP.
OFF (Default)
ON
Associate a function with the CX input.
Associate a function with input C1.
Check that the photocells connected to the inputs are
operating correctly, after each opening and closing
command.
With the function active, the operator stops moving
(opening or closing) when the control device is released.
When the function is active, it excludes all other
control devices.
Associate a command to the connected device on 2-7.
With the function active and the operator stopped, an
open or close command is not performed if the safety
devices detect an obstacle. The function is active when
the passage is closed or open, or after a complete stop.