PROGRAMMING
Programming button functions
Alert LED:
Control board powered up
Active programming
Getting started
Once the electrical connections have been made, proceed with commissioning. Only skilled and qualifi ed staff
may perform this operation.
Make sure that there are no obstacles in the way.
Power up the device and begin programming.
Complete programming and check the warning, safety and protection devices, and the manual release, are
working properly.
Perform the fi rst manoeuvre where you can see the gate in motion and with the photocells active, including
where remotely controlled.
Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or
vibrations, or unexpected behaviour in the system.
Functions menu
Function
F1 Total stop
1
ESC button
The ESC button is used to perform the operations described below.
- Exit the menu
- Delete the changes
- Go back to the previous screen
- Stop the operator (outside the programming menu)
2
< > buttons
The < > buttons are used to perform the operations described below.
- Navigate the menu
- Increase or decrease values
- Operator opening and closing (outside the programming menu)
3
ENTER button
The ENTER button is used to perform the operations described below.
- Access menus
- Confi rm choice
Parameters
OFF (Default)
ON
Function description
This stops the operator and excludes automatic closing.
Use a control device to resume movement.