Télécharger Imprimer la page

CAME ZC3N Manuel D'installation page 36

Masquer les pouces Voir aussi pour ZC3N:

Publicité

Size
215
Cable types and minimum thicknesses
Cable length (m)
Flashing beacon 230 V AC
Electric lock or electromagnetic lock
TX Photocells
RX photocells
Command and control devices
* no. = see product assembly instructions
Warning: the cable cross-section is indicative and varies according to the motor power and cable length.
When operating at 230 V and outdoors, use H05RN-F cables compliant with 60245 IEC 57 (IEC); when indoors,
use H05VV-F cables compliant with 60227 IEC 53 (IEC). For power supplies up to 48 V, use FROR 20-22 II cables
compliant with standard EN 50267-2-1 (CEI).
To connect the antenna, use RG58 cable (up to 5 m).
If the cable lengths diff er from those specifi ed in the table, defi ne the cable cross-sections according to the
actual power draw of the connected devices and in line with regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, recalculate the values in the table according to the actual
power draw and distances. For information on connecting products not covered in this manual, please see the
documentation accompanying the products themselves.
240
up to 20
2 x 1 mm²
2 x 1 mm²
2 x 0.5 mm²
4 x 0.5 mm²
*no. x 0.5 mm²
120
145
from 20 to 30
2 x 1 mm²
2 x 1 mm²
2 x 0.5 mm²
4 x 0.5 mm²
*no. x 0.5 mm²
165

Publicité