Automatic
F20
closing after
partial opening
Pre-fl ashing
F21
time
F22 Operating time
Courtesy light
F25
time
F26 Thrust time
Electric lock
F27
time
Manoeuvre
F48
thrust activation
F50 Save data
F51 Read data
F56 CRP address
1 to 180 seconds (Default 10)
OFF (Default)
1 to 10 seconds
10 to 150 seconds (Default 150)
60 to 180 seconds (Default 60)
1 to 2 seconds (Default 1)
1 to 4 seconds (Default 1)
OFF
ON (Default)
OFF (Default)
ON (Run operation)
OFF (Default)
ON (Run operation)
from 1 to 255 (Default 1)
Set the time before automatic closure after a partial
opening command.
The function does not work if any of the safety
devices are triggered when an obstacle is detected,
after a complete stop, during a power outage or if
there is an error.
Adjust the time for which the beacon is activated before
each manoeuvre.
Set the gearmotor working time during opening and
closing.
Defi ne how many seconds the additional light (set up
as courtesy light) stays on after an opening or closing
manoeuvre.
Adjust the gearmotor closing thrust after an opening
command.
The function is visible only with the electric lock
active [Function F17 set to 1].
Adjust the electric lock release time after an opening
command.
The function is visible only with the electric lock
active [Function F17 set to 1].
Adjust the thrust torque increase during opening and
closing.
Save user data, timings and confi gurations to the
memory device (memory roll).
The function is displayed only when a memory
roll card is inserted into the control board.
Upload user data, timings and confi gurations to the
memory device (memory roll).
The function is displayed only when a memory
roll card is inserted into the control board.
Assign a unique identifi cation code (CRP address) to the
control board.
The function is used where there are multiple
operators connected to the same communication
BUS using the CRP protocol.

Publicité

loading

Ce manuel est également adapté pour:

Zc3nc