8.2 Setting up the lift
Before setting up the lift, ensure that everything possible
is done to prevent accidents due to careless assembly.
This includes, above all, the use of safe auxiliary means
(e.g. cranes, forklifts and a sufficient number of people),
diverse supports and a sufficient barrier to prevent un-
authorised access.
• Carefully remove the lift from the wooden crate and
check for damage.
• Position the lift according to the data sheet at the de-
sired set up location.
• Set up the unit, connect power supply.
i
The set up location of the operating unit can be select-
ed from two variants. Either in the drive-in direction at
the front right or left.
• Fill with hydraulic oil, the manufacturer recommends a
high value hydraulic oil with a viscosity of 32 cst. The
required oil volume is approx. 14 litres. After filling,
the oil must be between the marks on the oil dipstick or
approx. 2 cm below the oil filling supports (11).
11 Oil filling supports
• Move the lifting upwards to approx. 1,500 mm.
• Check the alignment of the base plates again and an-
chor the lift. Holes for floor anchoring are to be placed
through the holes in the base plates.
Clean the bore holes by blowing them out with air. In-
sert safety anchors into the holes.
The manufacturer recommends using approved safety an-
chors and to follow anchor manufacturer's instructions.
Before anchoring the lift, check whether the concrete is
of quality C20/25 up to the finishing level of the com-
pleted floor. In this case, take the anchor length from
the anchor manufacturer's data sheet. If there is a floor
covering (tiles, screed) on the weight bearing concrete,
the thickness of this covering must be determined.
72
• Anchor the unit to the floor.
• Align the lift.
To prevent hollow spaces, correct any unevenness in the
floor by putting shims under the base frame (e.g. thin
metal strips). Use suitable supports to ensure continuous
contact between the floor and base frame.
• Tighten safety anchors with torques recommended by
the manufacturer.
Each anchor must be tightened to the re-
!
quired torque. Safe operation of the lift is
not guaranteed with a lower torque. Follow
the instructions of the anchor manufacturer.
• Move the lift upwards and downwards several times, then
check the anchors with the torque wrench and tighten if
required. Check the hydraulic lines for leak-tightness.
• Balance the lift again if required.
• Mount all hose covers.
• Anchor the foot bumpers (optional) included beside the
lift on the floor. For this, lower the lift to the lowest posi-
tion. Position the foot bumpers and permanently anchor
them Distance between the drive in rails and the foot
bumpers approx. 20 mm (foot bumpers may not touch
the drive in rails).
11
Position of the foot bumpers (optional)
002
Installing the push button
are installed on the mounting base by
snapping them into place.
Operation of the middle contacts is standard on push-
buttons without illuminated display, on/off pushbuttons,
mushroom-type pushbuttons and selector switches.
The mounting base and buttons
have clearly visible reference marks
so that the engagement process is
easy and intuitive.
The electrical
contacts and LED
lighting elements
OPI_JUMBO LIFT 4000 NT_V4.1_DE-EN-FR-ES-IT