PROBLEM
The appliance will not operate until
three minutes after it is switched on.
6.2.
Error messages on the display
ERROR MESSAGE
E2
E3
E4
6.3.
Overheating protection
The appliance is equipped with an overheating protection device that automatically switches it off under the following
conditions:
• The cooling function is activated and the room temperature is less than 15 °C.
• The cooling function is activated and the room temperature is above 43 °C.
• Dehumidification is activated and the room temperature is less than 15 °C.
When the appliance is switched off by the overheating protection, do the following:
1.
Remove the mains plug from the socket.
2.
Allow to cool for 30 minutes.
3.
If necessary, remove the cause of overheating:
• Check the air intakes and outlets and the air outlet duct for blockages. Remove the blockages.
• Check that there is at least 60 cm of free space on the sides of the appliance.
4.
Get the appliance ready for use again. Follow the instructions in section 3.3.2. Installing the appliance.
1 1
NOTICE!
• Risk of damage to the appliance. Keep an eye on the appliance for 30 minutes after it is switched on again following
a shutdown due to the activation of the overheating protection. If the appliance shows malfunctions or reactivates the
overheating protection, contact customer service.
POSSIBLE CAUSE
The internal protection of the
compressor slows down the start-up of
the appliance by three minutes.
POSSIBLE CAUSE
The room temperature sensor is
damaged.
The oil line evaporator sensor is
damaged.
The water tank is full.
POSSIBLE SOLUTION
Wait until the appliance is switched on.
The three-minute delay is normal.
POSSIBLE SOLUTION
Please contact customer service.
Empty the water tank. Follow the
instructions in section 4.6. Water
drainage.
43