1.18.4 Space Heating / Space Cooling configuration
Control the temperature for Space Heating or Space Cooling by configuring the following parameters.
Eco Offset Water setting:
Configure the offset water temperature for the ECO
mode for Space Heating or Space Cooling.
By using this function, current water temperature
setting is reduced by the indicated parameter.
Range: 0 ~ 10
PMEN0597 rev.1 - 06/2023
DHW configuration:
Selection of the water set point for
Circuit 1 or Circuit 2 (Space Heating
or Space Cooling).
• Deactivated
• Points
• Gradient (only in heating mode)
• Fix
• See detailed explanation below.
Working Limits:
Limit for the temperature set-point to
prevent high or low temperatures at
Space Heating or Space Cooling:
• Maximum supply temperature
• Minimum supply temperature
1