To protect surrounding surfaces from overheating, observe the above distances from the sides of
furniture.
B – Mains power connection
Warning:
The electrical connection of this appliance must be carried out by an approved
professional or a qualified electrician, in accordance with the instructions in this manual and in
compliance with current installation standards.
The cable is supplied with your appliance. This cable is connected to the cooker's connection box.
This is a 3x4x1.5 single-phase cable This appliance must be earthed: only use the power cable
already installed with your appliance. If the power cable is damaged, it must be replaced with
a cable or special kit available from the manufacturer or its after-sales service.
Your cooker is set up for 220-240V AC / 380- 415V AC, 50 Hz. If the current is different from this
specified value, please contact your authorised service centre.
This cooker can also be installed on three-phase voltage with an H05VV-5G 1.5 mm2
cable (not supplied) in accordance with the power supply used. (See electrical connection
diagram -380-415 3N-50/60Hz) The installation must be carried out by a qualified technician.
The manufacturer will never be held responsible for damage caused by connecting the appliance
to unearthed outlets.
Warning:
The oven must be earthed. The connection must comply with current regulations
(cable and plugs must have an earth wire). If there is no earth connection where the appliance is
due to be installed, contact a qualified electrician immediately. The manufacturer cannot be held
responsible for any damage to property or persons resulting from the appliance being connected
to an unearthed outlet.
Note: Don't forget to connect the earth plug to the cooker's terminal, marked with the
corresponding symbol.
The electrical supply to the cooker must be installed with an emergency stop circuit
breaker, enabling the electricity to be cut off at any time. The minimum distance between
emergency stop switch contacts is 3 mm.
Risk of electrocution! Before working on electrical parts, disconnect the power supply.