Pre-sweeping unit suction turbine belt
1
Brush roller drive belt (Under the sheet metal cover)
2
5. Check the brush roller drive belt for wear and correct
seating.
Checking the sweeping mechanism sealing strips
1. Place the device on a level surface.
2. Set the program selection switch to "0".
3. Use a chock to secure the device against rolling away.
4. Remove the waste containers from both sides.
Front sealing strip
5. Unscrew the nuts (5x).
6. Align the ground clearance of the sealing strip so that it
bends to the rear by 35-40 mm at the ground.
Nut
1
7. Tighten the nuts (5x).
26
Rear sealing strip
Adjust the ground clearance of the rear sealing strip so that
it bends to the rear by 5-10 mm at the ground.
8. Replace the sealing strip if it is worn.
9. Remove the roller brush (see chapter Replacing the
roller brush).
10.Unscrew the nuts (7x).
Nut
1
11.Fit the new sealing strip.
12.Tighten the nuts (7x).
Side sealing strips
13.Release the fastening nuts.
14.Adjust the ground clearance by inserting an underlay
1-2 mm thick.
15.Align the sealing strip.
16.Tighten the nuts.
17.Install the roller brush.
English