Télécharger Imprimer la page

Motorola APX NEXT XN Mode D'emploi page 116

Publicité

MN008401A01-AH
Chapter 28: Voice Announcement
VA Event
Self-check Fail
The following voice announcements are repeated every five minutes:
Over Temperature
RF Device Cumulative Over Temperature
RSM Cumulative Over Temperature
Battery Cumulative Over Temperature
NOTE: The Enhanced Mute Tones Operation setting in HZM is override to Disabled. While your radio
is in HZM, you are not allowed to use the Mute feature.
NOTE: If the Voice Announcement field is set to Enabled, after an interruption by a momentary tone
one of the following scenarios occurs:
If Suppress Replay field is Enabled, voice announcement replays.
If Suppress Replay field is Disabled, voice announcement turns off.
28.1
Voice Announcement Priority
An announcement with a lower priority is paused and then replayed after an announcement with a higher
priority has been completed.
Table 21: Voice Announcement Priority Levels
1: Highest, 7: Lowest
Priority
1
2
3
4
5
6
7
116
Description
Your radio detects any
of these self-diagnostic fail-
ures:
Antenna failure
RSM failure (HZM off)
Over temperature
Battery medium on pow-
er-up
Voice Announcement Events
Zone Announcement
Channel Announcement
Accessory Failure
Over Temperature
Out of Range
Self-Check Failure or Non-Fire Safety Standard model Certified RSM
Exit Hazard Zone Mode
Audible Message (Text-to-
Speech)
Self-check fail
Audio Volume
Level
Normal

Publicité

loading