GB
IE
IT
CH
-THE MESSAGE IS REACTIVATED UPON REMOVAL OF THE PROBE FROM THE JACK
-THE MESSAGE RESETS WHEN ERRORS OCCUR
Damaged heart probe, replace it
The red icon indicates malfunction and safety ERRORS. To solve them, read the MANUAL or contact
SERVICE; they require the machine to be restarted.
SAFETY message list:
"er01"
ALL FUNCTIONS ARE SWITCHED OFF
-Active on the following products: THERMOSTATIC APPLIANCES
-message warning of "temperature limit" being exceeded
-it occurs when the actual temperature reading (DETECTED AND NOT CONVERTED TO DISPLAY)
is higher than the limit temperature for the appliance in use (see individual cooking centre)
-it works by deactivating and preventing all settings except: LANGUAGE + OFF, the error triangle flashes and an
intermittent beep sound.
-THE FIRST ACTION IS TO TAP ON ANY POINT ON THE SCREEN, which will deactivate the beep sound and the
flashing of the error triangle
-THE MESSAGE IS RESET BY RESTARTING THE OFF/ON CONTROLLER
-THE MESSAGE IS RESET WHEN ERROR "er02" OR "er03" OCCURS
Exceeded limit temperature, turn off and see manual
"er02"
ALL FUNCTIONS ARE SWITCHED OFF
-Active on the following products: WITH SAFETY THERMOSTAT
-message warning that the mechanical safety thermostat has been activated,
-the message is activated 1 second after the cooking centre is turned on
80