Raised component, put it in working position to resume heating
"av04"
TEMPORARILY "PAUSES" THE HEATING
-Active on the following products: AUTOMATIC PASTA COOKER
-the "pre-loading alarm" message warns that an attempt is being made to reach the minimum safe water level (lower
electrode), but this appears to be unsuccessful.
-the message cannot be displayed when the cooking centre is activated: but only after the heating approval has been
activated at least once, INPUT 3 closing
-it occurs when the heating consent fails and INPUT 3 opens, and at the same time the solenoid valve SV1 is active,
INPUT 2 closed.
-It acts by preventing settings except: LANGUAGE + OFF, the warning triangle flashes and an intermittent beep will
sound.
-THE FIRST ACTION IS TO TAP ON ANY POINT ON THE SCREEN, which will deactivate the beep sound and the
flashing of the warning triangle
-CLICKING ON OK CAUSES THE MESSAGE TO RESET AND DISAPPEAR
-THE MESSAGE IS REACTIVATED AFTER CLOSING INPUT 3.
-THE MESSAGE RESETS WHEN ERRORS OCCUR
Prolonged time to restore water level, check for water or drain lever
"av05" (ONLY WITH 3-POLE JACK SOCKET)
CORE PROBE MALFUNCTION WARNING ON PROBE 2 INPUT
-Active on the following products: AUTOMATIC PASTA COOKER, FRYTOP/FIXED BRAISING PANS, CONTACT
GRILLE
-the "faulty component" message warns that the inserted probe is not reading or that the reading is out of range.
-it occurs when the probe is plugged into the jack on the PROBE 2 panel; since the jack has 3 poles, 2 of them detect the
physical presence of the probe and the third pole allows the faulty component to be identified
-It acts by preventing settings except: LANGUAGE + OFF, the warning triangle flashes and an intermittent beep will
sound.
-THE FIRST ACTION IS TO TAP ON ANY POINT ON THE SCREEN, which will deactivate the beep sound and the
flashing of the warning triangle
-CLICKING ON OK CAUSES THE MESSAGE TO RESET AND DISAPPEAR
if the probe is still inserted, it will not be possible to use it