Télécharger Imprimer la page

Lotus CPA-94ETT Instructions Pour L'installation Et L'emploi page 109

Publicité

GB
IE
IT
CH
ENERGY OPTIMISATION SYSTEM
This operating state is identified by the green leaf icon
above the unit of measurement, and is
activated when INPUT 4, normally closed by a jumper, is opened.
When this situation occurs, any resistive element must be blocked, so all outputs supplying the cooking resistors must be
set to "0" (always off), nothing else must be changed: timers, functions, settings, etc. must be maintained...
Any errors or messages that may occur during non-heating should be suspended.
WARNING/ERROR MESSAGES
WARNING/ERROR ICON:
the messages displayed can be of 2 types, identified by the WARNING
or the SAFETY type icon
.
The yellow icon indicates caution/support WARNINGS to HELP the operator to avoid errors or more serious
problems that block machine operation. Resolution is on-screen and without machine restart.
WARNING messages:
"av01"
TEMPORARILY "PAUSES" THE HEATING
-Active on the following products: THERMOSTATIC APPLIANCES
(products under evaluation; regardless of the "seconds" parameters, when set to 0 the warning is disabled)
-the "temperature drop" message warns of an abnormal drop in the actual temperature, including a possible short circuit
in probe 1.
-it occurs when the delta of the drop in the working temperature measured over 2 seconds (parameter) exceeds 40 degrees
(parameter).
-it works by pausing the heating and temporarily disabling some functions (see individual cooking centres) and preventing
other settings except for: LANGUAGE + OFF, the warning triangle flashes and an intermittent beep will sound.
-THE FIRST ACTION IS TO TAP ON ANY POINT ON THE SCREEN, which will deactivate the beep sound and the
flashing of the warning triangle
-THE MESSAGE RESETS AND DISAPPEARS AND IS REACTIVATED AGAIN BY CLICKING ON "OK': heating
is restarted, the functions temporarily set to "off" return to "on". (drop DELTA measurement restarts)
-THE MESSAGE RESETS WHEN ERRORS OCCUR
77

Publicité

loading

Ce manuel est également adapté pour:

Cpa-98ett