ENERGY OPTIMISATION SYSTEM
This operating state is identified by the green leaf icon
above the unit of measurement, and is
activated when INPUT 4, normally closed by a jumper, is opened.
When this situation occurs, any resistive element must be blocked, so all outputs supplying the cooking resistors must be
set to "0" (always off), nothing else must be changed: timers, functions, settings, etc. must be maintained...
Any errors or messages that may occur during non-heating should be suspended.
WARNING/ERROR MESSAGES
WARNING/ERROR ICON:
the messages displayed can be of 2 types, identified by the WARNING
or the SAFETY type icon
.
The yellow icon indicates caution/support WARNINGS to HELP the operator to avoid errors or more serious
problems that block machine operation. Resolution is on-screen and without machine restart.
WARNING messages:
"av01"
TEMPORARILY "PAUSES" THE HEATING
-Active on the following products: THERMOSTATIC APPLIANCES
(products under evaluation; regardless of the "seconds" parameters, when set to 0 the warning is disabled)
-the "temperature drop" message warns of an abnormal drop in the actual temperature, including a possible short circuit
in probe 1.
-it occurs when the delta of the drop in the working temperature measured over 2 seconds (parameter) exceeds 40 degrees
(parameter).
-it works by pausing the heating and temporarily disabling some functions (see individual cooking centres) and preventing
other settings except for: LANGUAGE + OFF, the warning triangle flashes and an intermittent beep will sound.
-THE FIRST ACTION IS TO TAP ON ANY POINT ON THE SCREEN, which will deactivate the beep sound and the
flashing of the warning triangle
-THE MESSAGE RESETS AND DISAPPEARS AND IS REACTIVATED AGAIN BY CLICKING ON "OK': heating
is restarted, the functions temporarily set to "off" return to "on". (drop DELTA measurement restarts)
-THE MESSAGE RESETS WHEN ERRORS OCCUR
77