Rotax 914 - MGL Avionics Stratomaster Série Utilisation Et Installation

Système de surveillance moteur
Table des Matières

Publicité

MGL Avionics
Max Oil Pressure Bargraph: 5 bar (70 PSI)
Oil Pressure Low Alarm: 2 bar (30 PSI)
Max Revs: 6000
High Rev Alarm: 5800 RPM (after 2 minutes)
Rev Counter Calibration: 10 pulses per 10 revs

Rotax 914

4 x EGT (K-type) thermocouples on inputs TC1, TC2, TC3, TC4
2 x CHT (ROTAX NTC) on inputs CHT1, CHT2
1 x ROTAX Oil Temp sender on input OILT
1 x ROTAX Oil Pressure sender (200 ohms) on input OILP
EGT Max Bargraph: 900 °C (1650 °F)
CHT Max Bargraph: 180 °C (1560 °F)
EGT High Alarm: 850 °C ( °F)
EGT Span Alarm: 25 °C (45 °F)
CHT High Alarm: 150 °C (300 °F)
Water Temp Max: 90 °C (190 °F)
Water Temp Alarm: 80 °C (180 °F)
Max Oil Temp Bargraph: 160 °C (320 °F)
Oil Temp High Alarm: 140 °C (280 °F)
Max Oil Pressure Bargraph: 5 bar (70 PSI)
Oil Pressure Low Alarm: 2 bar (30 PSI)
Max Revs: 7000
High Rev Alarm: 6700 RPM (after 6 minutes)
Rev Counter Calibration: 10 pulses per 10 revs
© 2004-2006 MGL & Delta Omega www.delta-omega.com