The LEDs light up or flash in different patterns to indicate the condition and state of charge (SOC). If
no LED is lit but the Mains indicator is lit blue, it indicates that the battery is not connected.
Parameter settings
CAUTION
Incorrect settings of the battery charger may dam-
age the battery. Always check settings before
start charging.
Check settings
NOTE
When the battery charger is configured for Battery
Management System (BMS) control, please
check the CAN setting.
Navigate in the charger's display as follows:
1. Press OK.
2. Go to [Service] using arrow down.
3. Press OK.
4. Go to [Charging param] or [CAN] using arrow
down.
5. Press OK.
Current settings are displayed.
Maintenance and
troubleshooting
WARNING
RISK OF ELECTRIC SHOCK!
Only qualified personnel should install, use,
maintain and service this product.
Disconnect the battery and power supply before
maintenance, servicing, or dismantling.
WARNING
RISK OF ELECTRIC SHOCK!
Do not use the battery charger if it is damaged.
Disconnect the mains immediately.
Do not touch damaged parts, uninsulated battery
terminals, connectors, or other live electrical
parts.
Contact service personnel.
8
Statistics
The charger is collecting charger data for data
analysis and service. The data can be accessed
through Service Tool or GET Cloud.
Safety shut-off
Charging can be terminated if:
The recharged number of ampere-hours
exceeds the preset value.
The charging time for any of the charging
phases exceeds the preset value.
Voltage and current exceed the maximum set
value.
The battery is disconnected without the
battery charger being stopped.
The BMS turns off the battery charger via
CAN bus.
The CAN bus communication with the battery
is interrupted.
Charging is temporarily stopped or reduced when:
The battery charger temperature exceeds
charger limits.
The BMS stops or reduces the charging via
CAN bus.